Solar Load Calculator — Pakistan
Tell this calculator what runs in your home — fans, lights, fridge, TV, pump, AC — and it works out your daily units, panel capacity and count, a sensible inverter size and the battery for night backup.
Your appliances
Change any quantity, watts or hours. Set quantity to 0 for anything you do not have.
| Appliance | Qty | Watts each | Hours / day |
|---|---|---|---|
| Ceiling fans | |||
| LED lights | |||
| Refrigerator (use effective running hours — a fridge cycles on and off) | |||
| LED TV | |||
| Washing machine | |||
| Water pump | |||
| Inverter AC (1.5 ton) | |||
| Laptop / desktop |
In short
Add up quantity × watts × hours to get daily energy. Divide by sun hours and efficiency for the panel watts you need, round up to whole panels, choose an inverter about 1.5 times your running load, and size the battery only for the share you need after dark.
How it works — the formula
Solar sizing is two separate questions. The first is about energy: how much electricity does your home use in a whole day? The second is about power: how much is switched on at the same moment? Panels and batteries answer the energy question; the inverter answers the power question. Mixing them up is the commonest reason a system disappoints — plenty of panels, yet the inverter trips when the pump starts.
The energy calculation is simple bookkeeping. For each appliance, multiply quantity × watts × hours to get its watt-hours (Wh), then add the rows together. Divide by 1,000 and you have kilowatt-hours — exactly what your bill calls units. A home using 5,132 Wh a day uses about 5.13 units a day, roughly 154 units a month.
Panels must replace that energy during daylight, minus real-world losses: the inverter, cables, dust, heat and imperfect angles. This calculator bundles them into one efficiency figure, 75% by default. Required panel watts = daily Wh ÷ (sun hours × efficiency). Only then do we divide by the size of one panel and round up — you cannot buy a fraction of a panel.
The inverter is sized from the running load — quantity × watts, no hours — multiplied by 1.5. The extra half is surge headroom: motors in fridges and pumps draw a brief spike at start-up, and an exactly-sized inverter trips on it. The battery works backwards from the night: take the share of daily energy you want after sunset, convert it to amp-hours at your voltage, and divide by the usable share — about 80% for lithium, only 50% for lead-acid.
Worked example — the default home
The calculator opens with a modest home already filled in: four fans, six LED lights, a fridge and a TV. Here is the arithmetic, exactly as the tool does it.
Daily energy = 4×75×10 + 6×12×6 + 1×150×8 + 1×100×5 = 3,000 + 432 + 1,200 + 500 = 5,132 Wh ≈ 5.13 units/day. The fans dominate — 3,000 of the 5,132 Wh — which is typical: a fan is a small load, but ten hours is a long time. Required panels = 5,132 ÷ (5 × 0.75) = 1,369 W → 3 panels of 585 W (1,755 W installed). Three panels is the first whole number covering 1,369 W; two panels (1,170 W) would fall short on dull days.
Running load = 622 W → minimum inverter 1,000 W (622 × 1.5 surge headroom = 933 W, rounded up to the next standard size). Battery for 40% night share: 2,052.8 Wh ÷ (24 V × 0.80) = 106.9 Ah → a 24 V, ~110 Ah lithium battery. In plain terms: a roughly 1.8 kW system with a 1 kW inverter runs this home's fans, lights, fridge and TV, with 40% of the day's energy held back for the evening. Add an AC and every number changes — try it above and watch the panel count jump.
Peak sun hours by city
“Peak sun hours” does not mean hours of daylight. It means the day's total sunlight expressed as equivalent hours of full-strength sun. Use your city's figure as the starting point, and remember winter values are lower everywhere — a system sized on the annual average will import some grid power in December and have surplus in June.
| City | Approx. peak sun hours (annual average) |
|---|---|
| Karachi | 5.5 |
| Lahore | 5.0 |
| Islamabad | 5.0 |
| Multan | 5.5 |
| Faisalabad | 5.2 |
| Peshawar | 5.0 |
| Quetta | 5.8 |
| Hyderabad | 5.6 |
Approximate annual averages for planning only — roof direction, tilt, shading and weather move your real figure.
A useful cross-check: in most of Pakistan, 1 kW of panels generates roughly 4–5 units a day across the year. If a quote promises far more from the same capacity, ask how. And “system size in kW” simply means total panel watts ÷ 1,000 — a “5 kW system” has 5,000 W of panels, whatever inverter is fitted.
Panels, inverters and batteries — what to know before you buy
Panels sold in Pakistan are commonly 545–585 W each, with newer 600 W+ models appearing, so compare quotes by total installed watts and price per watt, not by panel count. A hybrid inverter lets you run solar + grid + battery together, using the battery during outages; a plain on-grid inverter is cheaper and can export surplus under net metering, but it switches off when the grid fails — even at noon — and net metering needs approval from your DISCO (LESCO, IESCO, K-Electric and so on) before exports are credited.
Two warnings matter more than brand names. First, loadshedding backup depends on the battery, not the panels — only stored energy carries you through a night outage. Second, the AC is the load that changes everything: one 1.5-ton inverter AC at 8 hours adds ~9.6 units/day at full draw, nearly double the entire default home above. In practice an inverter AC averages well below nameplate once the room cools, so treat the tool's AC figure as a cautious upper bound. Either way, decide the AC question first — “fans and lights only” and “one AC all night” are different purchases at very different prices.
How to use this calculator
- Set the quantity for each appliance you own; zero the rest.
- Adjust watts if your appliance's sticker differs, and set honest hours — for the fridge, effective hours, not 24.
- Pick your city's sun hours from the table; leave efficiency at 75% unless an installer justifies another figure.
- Set the battery backup share to what you truly need after sunset — 40% is a sensible start.
- Press Calculate and take the panel count, inverter size and battery Ah to installers for like-for-like quotes.
Frequently asked questions
How many solar panels do I need for 300 units a month?
Work it in three steps. 300 units ÷ 30 days = 10 units a day (10,000 Wh). Required watts = 10,000 ÷ (5 sun hours × 0.75) = about 2,667 W. Divided by 585 W panels that is 4.6, so round up to 5 panels — about 2.9 kW installed. Change the sun hours or efficiency and the count changes with them.
What size solar system do I need for a 1.5-ton inverter AC?
At its 1,200 W rating, eight hours is about 9.6 units a day for the AC alone, though a real inverter AC averages well below nameplate once the room cools. Budget roughly 2.5–3 kW of panels for daytime AC use and an inverter of at least 3 kW — plus a much larger battery if the AC must run through night outages.
Should I choose an on-grid or a hybrid solar system?
On-grid is cheaper and earns export credit through net metering, but it needs DISCO approval and gives you nothing during loadshedding. Hybrid costs more because of the battery, but keeps essential loads alive in an outage. With regular loadshedding, hybrid is the practical choice; with a reliable grid supply, on-grid can be enough.
Why does the calculator include efficiency losses?
Because panel watts are measured in a laboratory. Between panel and appliance sit an inverter, cables, heat, dust and imperfect angles, together typically taking about a quarter of the energy. Ignoring them undersizes the system by that same quarter — the classic reason a “correctly calculated” system still buys grid units every month.
Do I need a battery with my solar system?
Only for power when the sun is not shining. If your load is mostly daytime and the grid is reliable, skip it — the battery is the most expensive, shortest-lived part. If evening loadshedding is your main pain, the battery is the whole point; size it from the backup share, not the full day's energy.
Does a 585 W panel give 585 watts all day?
No. That figure is a peak under standard test conditions. Output climbs through the morning, peaks near midday and falls by evening, and hot roof temperatures pull it down further. What matters over a day is total energy — exactly what the peak-sun-hours method here estimates.